DM SIGNAL PTFE d.o.o. - 01-014188 / 0110651 2024-08-06
DM SIGNAL PTFE d.o.o. Modul D 01-014191 / 0110651 2024-08-07
I.S.T. Isci Sagligi Techizati Fire-fighter’s outfit type FYRAL 9000, Product Code no. 13303900 is comprised of: 1)JACKET made with assembly of materials, collar, front opening closed by double flap and hook and loop tape, long sleeves and cuff adjustable by frog fastening by hook and loop tape, 2)TROUSER with bib and adjustable shoulders straps with plastic closure, central openings covered by flap closed by hook and loop tape, 3)5-FINGER GLOVES with hose adjustable by hook and loop tape, 4)Protective OVER BOOTS and 5)HOOD inside helmet fastened with snaps, adjustable straps under the armpits with plastic closure (glass screen/Visor: article no. ZFKGL203) 01-013517 / 019997 2023-06-28
I.S.T. Isci Sagligi Techizati Fire-fighter’s outfit type FYRPRO 800, Product Code no. 13152366 comprising of jacket and trousers with retroreflective stripes, 5 cm wide (fluorescent yellow / retroreflective silver / fluorescent yellow) meets performance levels: Xf2, Xr2, Y2 and Z2. 01-013518 / 019997 2023-06-28
I.S.T. Isci Sagligi Techizati Module D for fire-fighter's outfits. EC QUALITY SYSTEM (MODULE D) CERTIFICATE 01-014011 / 019997 2023-06-28
MARINE ELEVATOR d.o.o. “A-60” Vertical bi-parting sliding doors for use on dumbwaiters A lift door construction consist of two door leaves and frame. Door leaves(panels) are made of 1.5 mm stainless steel plate and non-combustible panel Promaxon Type A (10 mm thickness, nominal density 850 kg/m3) glued to the steel with Promat - Kleber K84 glue. Panels are stiffened with “C” profile 50/20/8 mm, fixed with spot welding bolts to the panels and corner reinforcement. The panels travel through the vertical rail profile. Door panels are manually operated by steel cable divert rool and steel cable. Steel cable is fixed with rope holder to the upper corner reinforcement of lower panel and other end of the cable is fixed over the cable divert roller to the upper corner reinforcement of the upper panel. 01-013473 / 019892 2023-08-14
MARINE ELEVATOR d.o.o. A-0” class platform double leaf hinged door for lifts. A lift door construction consist of two door leaves and frame. Door leaves are made of 2 steel sheets 1.5 mm thick which are welded together. Two U shaped reinforcement profiles made of 1.5 mm steel sheets are welded between the two sheets of the leaf, one on the upper side and one on the lower side. Distance between two sheets is 52 mm. 01-013474 / 019892 2023-08-14
PASTOR - INŽENJERING D.D. Nozzles for fixed pressure water spraying fire extinguishing systems for ro-ro spaces and for special category spaces Type K 57 02-002631 / 024622 2023-04-15
SCOTT HEALTH & SAFETY Ltd Modul D / SCBA i EEBD EC QUALITY SYSTEM (MODULE D) CERTIFICATE 01-013321 / 019828 2022-06-01
SCOTT HEALTH & SAFETY Ltd OPEN CIRCUIT POSITIVE PRESSURE SELF-CONTAINED BREATHING APPARATUS, Type 2 Model: Sigma2 Type 2 using Face Mask type Vision 3 or Promask. 01-013319 / 019828 2023-06-01